Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Transl Vis Sci Technol ; 13(4): 19, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38607632

RESUMO

Purpose: To investigate whether fractal dimension (FD), a retinal trait relating to vascular complexity and a potential "oculomics" biomarker for systemic disease, is applicable to a mixed-age, primary-care population. Methods: We used cross-sectional data (96 individuals; 183 eyes; ages 18-81 years) from a university-based optometry clinic in Glasgow, Scotland, to study the association between FD and systemic health. We computed FD from color fundus images using Deep Approximation of Retinal Traits (DART), an artificial intelligence-based method designed to be more robust to poor image quality. Results: Despite DART being designed to be more robust, a significant association (P < 0.001) between image quality and FD remained. Consistent with previous literature, age was associated with lower FD (P < 0.001 univariate and when adjusting for image quality). However, FD variance was higher in older patients, and some patients over 60 had FD comparable to those of patients in their 20s. Prevalent systemic conditions were significantly (P = 0.037) associated with lower FD when adjusting for image quality and age. Conclusions: Our work suggests that FD as a biomarker for systemic health extends to mixed-age, primary-care populations. FD decreases with age but might not substantially decrease in everyone. This should be further investigated using longitudinal data. Finally, image quality was associated with FD, but it is unclear whether this finding is measurement error caused by image quality or confounded by age and health. Future work should investigate this to clarify whether adjusting for image quality is appropriate. Translational Relevance: FD could potentially be used in regular screening settings, but questions around image quality remain.


Assuntos
Inteligência Artificial , Fractais , Humanos , Idoso , Estudos Transversais , Retina , Biomarcadores
2.
BMC Med Res Methodol ; 24(1): 13, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38233744

RESUMO

BACKGROUND: Community optometrists in Scotland have performed regular free-at-point-of-care eye examinations for all, for over 15 years. Eye examinations include retinal imaging but image storage is fragmented and they are not used for research. The Scottish Collaborative Optometry-Ophthalmology Network e-research project aimed to collect these images and create a repository linked to routinely collected healthcare data, supporting the development of pre-symptomatic diagnostic tools. METHODS: As the image record was usually separate from the patient record and contained minimal patient information, we developed an efficient matching algorithm using a combination of deterministic and probabilistic steps which minimised the risk of false positives, to facilitate national health record linkage. We visited two practices and assessed the data contained in their image device and Practice Management Systems. Practice activities were explored to understand the context of data collection processes. Iteratively, we tested a series of matching rules which captured a high proportion of true positive records compared to manual matches. The approach was validated by testing manual matching against automated steps in three further practices. RESULTS: A sequence of deterministic rules successfully matched 95% of records in the three test practices compared to manual matching. Adding two probabilistic rules to the algorithm successfully matched 99% of records. CONCLUSIONS: The potential value of community-acquired retinal images can be harnessed only if they are linked to centrally-held healthcare care data. Despite the lack of interoperability between systems within optometry practices and inconsistent use of unique identifiers, data linkage is possible using robust, almost entirely automated processes.


Assuntos
Registro Médico Coordenado , Prontuários Médicos , Humanos , Sistemas Computadorizados de Registros Médicos , Coleta de Dados , Escócia
3.
JMIR Hum Factors ; 10: e40887, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37227761

RESUMO

BACKGROUND: A repository of retinal images for research is being established in Scotland. It will permit researchers to validate, tune, and refine artificial intelligence (AI) decision-support algorithms to accelerate safe deployment in Scottish optometry and beyond. Research demonstrates the potential of AI systems in optometry and ophthalmology, though they are not yet widely adopted. OBJECTIVE: In this study, 18 optometrists were interviewed to (1) identify their expectations and concerns about the national image research repository and their use of AI decision support and (2) gather their suggestions for improving eye health care. The goal was to clarify attitudes among optometrists delivering primary eye care with respect to contributing their patients' images and to using AI assistance. These attitudes are less well studied in primary care contexts. Five ophthalmologists were interviewed to discover their interactions with optometrists. METHODS: Between March and August 2021, 23 semistructured interviews were conducted online lasting for 30-60 minutes. Transcribed and pseudonymized recordings were analyzed using thematic analysis. RESULTS: All optometrists supported contributing retinal images to form an extensive and long-running research repository. Our main findings are summarized as follows. Optometrists were willing to share images of their patients' eyes but expressed concern about technical difficulties, lack of standardization, and the effort involved. Those interviewed thought that sharing digital images would improve collaboration between optometrists and ophthalmologists, for example, during referral to secondary health care. Optometrists welcomed an expanded primary care role in diagnosis and management of diseases by exploiting new technologies and anticipated significant health benefits. Optometrists welcomed AI assistance but insisted that it should not reduce their role and responsibilities. CONCLUSIONS: Our investigation focusing on optometrists is novel because most similar studies on AI assistance were performed in hospital settings. Our findings are consistent with those of studies with professionals in ophthalmology and other medical disciplines: showing near universal willingness to use AI to improve health care, alongside concerns over training, costs, responsibilities, skill retention, data sharing, and disruptions to professional practices. Our study on optometrists' willingness to contribute images to a research repository introduces a new aspect; they hope that a digital image sharing infrastructure will facilitate service integration.

4.
Eye (Lond) ; 37(16): 3376-3381, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36959313

RESUMO

BACKGROUND: Socioeconomic deprivation is associated with higher odds of chronic diseases, with many individuals living with more than one illness. This study aimed to examine the relationship between deprivation and severity of glaucoma at diagnosis, an important risk factor for glaucoma blindness. METHODS: A retrospective study of 472 consecutive patients referred by community optometrists to the glaucoma clinic at a university hospital was performed. Glaucoma severity was determined by standard automated perimetry mean deviation (MD) in the worse eye. The Scottish Index of Multiple Deprivation (SIMD) was determined for each patient as a measure of deprivation based on postcode. Regression analyses were performed to determine the relationship between visual field MD and SIMD. RESULTS: There was a significant relationship between higher levels of deprivation (lower SIMD) and worse severity of glaucoma at diagnosis. 32 of 472 patients (6.8%) had a MD of ≤-6 dB and 11 (2.3%) ≤-12 dB in their better eye. MD in the worse eye was 0.04 dB (95% CI 0.014 to 0.062 dB, P = 0.002) worse for each 100-point decrease in SIMD, with lower SIMD indicating a higher level of deprivation. A higher proportion of patients living in most deprived areas had a MD ≤ -6 dB or ≤ -12 dB at presentation compared to those living in the least deprived areas (14.3% versus 6.8% for ≤ -6 dB and 4.8% versus 0.8% for ≤ -12 dB). CONCLUSIONS: Higher levels of deprivation were associated with worse glaucoma severity at presentation. The reasons for poorer outcomes in those from more deprived communities need further study so that inequalities can be addressed and the frequency of patients presenting with advanced glaucoma reduced.


Assuntos
Glaucoma , Transtornos da Visão , Humanos , Estudos Retrospectivos , Transtornos da Visão/diagnóstico , Transtornos da Visão/etiologia , Glaucoma/diagnóstico , Glaucoma/complicações , Campos Visuais , Testes de Campo Visual , Índice de Gravidade de Doença
5.
Transl Vis Sci Technol ; 10(3): 14, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34003948

RESUMO

Purpose: To examine the feasibility of saccadic vector optokinetic perimetry (SVOP), an automated eye tracking perimeter, as a tool for visual field (VF) assessment in infants. Methods: Thirteen healthy infants aged between 3.5 and 12.0 months were tested binocularly using an adapted SVOP protocol. SVOP uses eye tracking technology to measure gaze responses to stimuli presented on a computer screen. Modifications of SVOP for testing infants included adjusting the fixation target to display a short animation, increasing the stimulus size to equivalent to Goldmann V, and introducing a tiered test pattern strategy. Binocular, single-quadrant confrontation VF testing and Keeler preferential looking cards visual acuity testing was also performed. Results: Using multiple test attempts when required, all but the youngest infant (12 of 13 [92.3%]) successfully completed a 4-point screening test. Seven infants (53.8%) successfully completed the 12-point test, four (30.8%) successfully completed the 20-point test, and three (23.1%) successfully completed the 40-point test. The effect of multiple test attempts and the complexity of the test pattern (number of test points) on performance was investigated, including test completion rate, percentage of correctly seen stimuli, and average time per tested stimulus. Conclusions: The modified SVOP test strategy allowed successful assessment of binocular VFs in healthy infants. Future data collection from larger cohorts of infants is needed to derive normative limits of detection and assess accuracy in detecting and monitoring infant VF abnormalities. Translational Relevance: Eye tracking perimetry may provide a useful method of automated VF assessment in infants.


Assuntos
Testes de Campo Visual , Campos Visuais , Estudos de Viabilidade , Humanos , Lactente , Movimentos Sacádicos , Testes Visuais
6.
Sci Rep ; 11(1): 839, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33436922

RESUMO

To explore the feasibility of using Saccadic Vector Optokinetic Perimetry (SVOP) to differentiate glaucomatous and healthy eyes. A prospective case-control study was performed using a convenience sample recruited from a single university glaucoma clinic and a group of healthy controls. SVOP and standard automated perimetry (SAP) was performed with testing order randomised. The reference standard was a diagnosis of glaucoma based a comprehensive ophthalmic examination and abnormality on standard automated perimetry (SAP). The index test was SVOP. 31 patients with glaucoma and 24 healthy subjects were included. Mean SAP mean deviation (MD) in those with glaucoma was - 8.7 ± 7.4 dB, with mean SAP and SVOP sensitivities of 23.3 ± 0.9 dB and 22.1 ± 4.3 dB respectively. Participants with glaucoma were significantly older. On average, SAP sensitivity was 1.2 ± 1.4 dB higher than SVOP (95% limits of agreement = - 1.6 to 4.0 dB). SVOP sensitivity had good ability to differentiate healthy and glaucomatous eyes with a 95% CI for area under the curve (AUC) of 0.84 to 0.96, similar to the performance of SAP sensitivity (95% CI 0.86 to 0.97, P = 0.60). For 80% specificity, SVOP had a 95% CI sensitivity of 75.7% to 94.8% compared to 77.8% to 96.0% for SAP. SVOP took considerably longer to perform (514 ± 54 s compared to 267 ± 76 s for SAP). Eye tracking perimetry may be useful for detection of glaucoma but further studies are needed to evaluate SVOP within its intended sphere of use, using an appropriate design and independent reference standard.


Assuntos
Glaucoma/diagnóstico , Testes de Campo Visual/métodos , Idoso , Área Sob a Curva , Estudos de Casos e Controles , Tecnologia de Rastreamento Ocular , Estudos de Viabilidade , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Estudos Prospectivos , Movimentos Sacádicos/fisiologia
7.
J Glaucoma ; 29(12): 1106-1114, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33264163

RESUMO

PRECIS: Normal age-corrected threshold sensitivity values were determined for a new eye tracking perimeter and compared with standard automated perimetry (SAP). PURPOSE: The purpose of this study was to determine threshold visual field sensitivities in normal subjects performing saccadic vector optokinetic perimetry (SVOP), a new eye tracking perimeter. PATIENTS AND METHODS: A total of 113 healthy participants performed SVOP and SAP in both eyes with the order of testing randomized. The relationship between SAP and SVOP sensitivity was examined using Bland-Altman plots and 95% limits of agreement. The relationship between sensitivity and age was examined by pointwise linear regression and age-corrected normal threshold sensitivities were calculated. RESULTS: After excluding unreliable tests, 97 participants with a mean age of 65.9±10.1 years were included. Average SAP mean deviation was -0.87±1.56 dB, SAP sensitivity was 29.20±1.68 dB and SVOP sensitivity was 32.18±1.96 dB. SVOP had a longer test duration (431±110 compared with 307±42 seconds for SAP, P<0.001). On average, the mean sensitivity obtained using SVOP was 2.98 dB higher than average SAP sensitivity, with 95% limits of agreement of -0.11 to 6.15 dB. For each decade older, SAP sensitivity decreased by 0.93 dB (95% confidence interval: 1.21 to 0.64) and SVOP sensitivity decreased by 1.15 dB (95% confidence interval: 1.47 to 0.84). CONCLUSIONS: The results provide age-corrected normative values for threshold sensitivities from SVOP. Overall, SVOP provided a similar shaped hill of vision as SAP however threshold sensitivities were higher, meaning results are not interchangeable.


Assuntos
Valores de Referência , Movimentos Sacádicos/fisiologia , Testes de Campo Visual , Campos Visuais/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Voluntários Saudáveis , Humanos , Pressão Intraocular , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Limiar Sensorial , Fatores de Tempo , Acuidade Visual/fisiologia
8.
BMC Ophthalmol ; 20(1): 259, 2020 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-32605609

RESUMO

BACKGROUND: To examine the speed and accuracy of saccadic eye movements during a novel eye tracking threshold visual field assessment and determine whether eye movement parameters may improve ability to detect glaucoma. METHODS: A prospective study including both eyes of 31 patients with glaucoma and 23 controls. Standard automated perimetry (SAP) and eye tracking perimetry (saccadic vector optokinetic perimetry, SVOP) was performed. SVOP provided data on threshold sensitivity, saccade latency, and two measures of accuracy of saccades (direction bias and amplitude bias). The relationship between eye movement parameters and severity of glaucoma was examined and Receiver Operating Characteristic curves were used to assess ability to detect glaucoma. RESULTS: Patients with glaucoma had significantly slower saccades (602.9 ± 50.0 ms versus 578.3 ± 44.6 ms for controls, P = 0.009) and reduced saccade accuracy (direction bias = 7.4 ± 1.8 versus 6.5 ± 1.5 degrees, P = 0.006). There was a significant slowing of saccades and saccades became less accurate with worsening SAP sensitivity. Slower saccades were associated with increased odds of glaucoma; however, the AUC for saccade latency was only 0.635 compared to 0.914 for SVOP sensitivity. CONCLUSION: Patients with glaucoma had significant differences in eye movements compared to healthy subjects, with a relationship between slower and less accurate eye movements and worse glaucoma severity. However, in a multivariable model, eye movement parameters were not of additional benefit in differentiating eyes with glaucoma from healthy controls.


Assuntos
Glaucoma , Movimentos Sacádicos , Tecnologia de Rastreamento Ocular , Glaucoma/diagnóstico , Humanos , Estudos Prospectivos , Campos Visuais
9.
Eye (Lond) ; 32(10): 1563-1573, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29880917

RESUMO

PURPOSE: To determine the ability of Saccadic Vector Optokinetic Perimetry (SVOP) to detect and characterise visual field defects in children with brain tumours using eye-tracking technology, as current techniques for assessment of visual fields in young children can be subjective and lack useful detail. METHODS: Case-series study of children receiving treatment and follow-up for brain tumours at the Royal Hospital for Sick Children in Edinburgh from April 2008 to August 2013. Patients underwent SVOP testing and the results were compared with clinically expected visual field patterns determined by a consensus panel after review of clinical findings, neuroimaging, and where possible other forms of visual field assessment. RESULTS: Sixteen patients participated in this study (mean age of 7.2 years; range 2.9-15 years; 7 male, 9 female). Twelve children (75%) successfully performed SVOP testing. SVOP had a sensitivity of 100% and a specificity of 50% (positive predictive value of 80% and negative predictive value of 100%). In the true positive and true negative SVOP results, the characteristics of the SVOP plots showed agreement with the expected visual field. Six patients were able to perform both SVOP and Goldmann perimetry, these demonstrated similar visual fields in every case. CONCLUSION: SVOP is a highly sensitive test that may prove to be extremely useful for assessing the visual field in young children with brain tumours, as it is able to characterise the central 30° of visual field in greater detail than previously possible with older techniques.


Assuntos
Neoplasias Encefálicas/complicações , Movimentos Sacádicos/fisiologia , Transtornos da Visão/diagnóstico , Testes de Campo Visual/métodos , Campos Visuais/fisiologia , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Sensibilidade e Especificidade , Transtornos da Visão/fisiopatologia , Testes de Campo Visual/instrumentação
10.
Transl Vis Sci Technol ; 6(5): 3, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28900576

RESUMO

PURPOSE: We evaluated threshold saccadic vector optokinetic perimetry (SVOP) and compared results to standard automated perimetry (SAP). METHODS: A cross-sectional study was done including 162 subjects (103 with glaucoma and 59 healthy subjects) recruited at a university hospital. All subjects underwent SAP and threshold SVOP. SVOP uses an eye tracker to monitor eye movement responses to stimuli and determines if stimuli have been perceived based on the vector of the gaze response. The test pattern used was equivalent to SAP 24-2 and stimuli were presented at Goldmann III. Average and pointwise sensitivity values obtained from both tests were compared using Pearson's correlation coefficient. Two versions of SVOP were evaluated. RESULTS: A total of 124 tests were performed with SAP and SVOP version 2. There was excellent agreement between mean threshold values obtained using SVOP and SAP (r = 0.95, P < 0.001). Excluding the blind spot, correlation between SVOP and SAP individual test point sensitivity ranged from 0.61 to 0.90, with 48 of 54 (89%) test points > 0.70. Overall SVOP showed good repeatability with a Pearson correlation of 0.88. The repeatability on a point-by-point basis ranged from 0.66 to 0.98, with 45 of 54 points (83%) > 0.80. Repeatability of SAP was 0.87, ranging from 0.69 to 0.96, with 47 of 54 (87%) points > 0.80. CONCLUSION: Eye-tracking perimetry is repeatable and compares well with the current gold standard of SAP. The technique has advantages over conventional perimetry and could be useful for evaluating glaucomatous visual field loss, particularly in patients who may struggle with conventional perimetry. TRANSLATIONAL RELEVANCE: Suprathreshold SVOP already is in the field. To our knowledge, this is the first report of threshold SVOP and provides a benchmark for future iterations.

11.
Transl Vis Sci Technol ; 6(5): 4, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28900577

RESUMO

PURPOSE: We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. METHODS: A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields from both devices were categorized by masked graders as: 0, normal; 1, paracentral defect; 2, nasal step; 3, arcuate defect; 4, altitudinal; 5, biarcuate; and 6, end-stage field loss. SVOP and SAP classifications were cross-tabulated. Subjects completed a questionnaire on their opinions of each test. RESULTS: We analyzed 142 (v1) and 111 (v2) SVOP and SAP test pairs. SVOP v2 had a sensitivity of 97.7% and specificity of 77.9% for identifying normal versus abnormal visual fields. SAP and SVOP v2 classifications showed complete agreement in 54% of glaucoma patients, with a further 23% disagreeing by one category. On repeat testing, 86% of SVOP v2 classifications agreed with the previous test, compared to 91% of SAP classifications; 71% of subjects preferred SVOP compared to 20% who preferred SAP. CONCLUSIONS: Eye-tracking perimetry can be used to obtain threshold visual field sensitivity values in patients with glaucoma and produce maps of visual field defects, with patterns exhibiting close agreement to SAP. Patients preferred eye-tracking perimetry compared to SAP. TRANSLATIONAL RELEVANCE: This first report of threshold eye tracking perimetry shows good agreement with conventional automated perimetry and provides a benchmark for future iterations.

12.
Transl Vis Sci Technol ; 5(4): 15, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27617181

RESUMO

PURPOSE: To evaluate feasibility, accuracy, and repeatability of suprathreshold Saccadic Vector Optokinetic Perimetry (SVOP) by comparison with Humphrey Field Analyzer (HFA) perimetry. METHODS: The subjects included children with suspected field defects (n = 10, age 5-15 years), adults with field defects (n = 33, age 39-78 years), healthy children (n = 12, age 6-14 years), and healthy adults (n = 30, age 16-61 years). The test protocol comprised repeat suprathreshold SVOP and HFA testing with the C-40 test pattern. Feasibility was assessed by protocol completeness. Sensitivity, specificity, and accuracy of SVOP was established by comparison with reliable HFA tests in two ways: (1) visual field pattern results (normal/abnormal), and (2) individual test point outcomes (seen/unseen). Repeatability of each test type was assessed using Cohen's kappa coefficient. RESULTS: Of subjects, 82% completed a full protocol. Poor reliability of HFA testing in child patients limited the robustness of comparisons in this group. Sensitivity, specificity, and accuracy across all groups when analyzing the visual field pattern results was 90.9%, 88.5%, and 89.0%, respectively, and was 69.1%, 96.9%, and 95.0%, respectively, when analyzing the individual test points. Cohen's kappa coefficient for repeatability of SVOP and HFA was excellent (0.87 and 0.88, respectively) when assessing visual field pattern results, and substantial (0.62 and 0.74, respectively) when assessing test point outcomes. CONCLUSIONS: SVOP was accurate in this group of adults. Further studies are required to assess SVOP in child patient groups. TRANSLATIONAL RELEVANCE: SVOP technology is still in its infancy but is used in a number of centers. It will undergo iterative improvements and this study provides a benchmark for future iterations.

13.
PLoS One ; 11(4): e0153757, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27124303

RESUMO

We report molecular genetic analysis of 42 affected individuals referred with a diagnosis of aniridia who previously screened as negative for intragenic PAX6 mutations. Of these 42, the diagnoses were 31 individuals with aniridia and 11 individuals referred with a diagnosis of Gillespie syndrome (iris hypoplasia, ataxia and mild to moderate developmental delay). Array-based comparative genomic hybridization identified six whole gene deletions: four encompassing PAX6 and two encompassing FOXC1. Six deletions with plausible cis-regulatory effects were identified: five that were 3' (telomeric) to PAX6 and one within a gene desert 5' (telomeric) to PITX2. Sequence analysis of the FOXC1 and PITX2 coding regions identified two plausibly pathogenic de novo FOXC1 missense mutations (p.Pro79Thr and p.Leu101Pro). No intragenic mutations were detected in PITX2. FISH mapping in an individual with Gillespie-like syndrome with an apparently balanced X;11 reciprocal translocation revealed disruption of a gene at each breakpoint: ARHGAP6 on the X chromosome and PHF21A on chromosome 11. In the other individuals with Gillespie syndrome no mutations were identified in either of these genes, or in HCCS which lies close to the Xp breakpoint. Disruption of PHF21A has previously been implicated in the causation of intellectual disability (but not aniridia). Plausibly causative mutations were identified in 15 out of 42 individuals (12/32 aniridia; 3/11 Gillespie syndrome). Fourteen of these mutations presented in the known aniridia genes; PAX6, FOXC1 and PITX2. The large number of individuals in the cohort with no mutation identified suggests greater locus heterogeneity may exist in both isolated and syndromic aniridia than was previously appreciated.


Assuntos
Aniridia/genética , Ataxia Cerebelar/genética , Deficiência Intelectual/genética , Fator de Transcrição PAX6/genética , Cromossomos Humanos Par 11/genética , Cromossomos Humanos X/genética , Hibridização Genômica Comparativa/métodos , Feminino , Fatores de Transcrição Forkhead/genética , Proteínas Ativadoras de GTPase/genética , Testes Genéticos/métodos , Histona Desacetilases/genética , Proteínas de Homeodomínio/genética , Humanos , Masculino , Mutação/genética , Fatores de Transcrição/genética , Proteína Homeobox PITX2
14.
Artigo em Inglês | MEDLINE | ID: mdl-24110017

RESUMO

The accurate assessment of visual field function can provide valuable information on a range of visual disorders. Saccadic Vector Optokinetic Perimetry (SVOP) is a novel instrument for measuring supra-threshold visual fields in young children who are otherwise unable to perform Automated Static Perimetry (ASP). However, limitations in Liquid Crystal Display (LCD) technology restrict the ability of SVOP to determine threshold values at various points in the visual field, often required in detailed perimetry examinations. This paper introduces a purpose-specific LCD luminance non-uniformity compensation approach to address this limitation. Thorough quantitative evaluation identifies the effectiveness of the proposed approach in (i) compensating for luminance non-uniformities across an LCD, and (ii) enabling SVOP to perform accurate and precise threshold visual field tests. The findings demonstrate that SVOP provides a promising alternative to the current threshold ASP standard (Humphrey Field Analyser).


Assuntos
Transtornos da Visão/diagnóstico , Testes de Campo Visual/métodos , Adulto , Idoso , Algoritmos , Humanos , Cristais Líquidos/química , Medições Luminescentes , Pessoa de Meia-Idade , Testes de Campo Visual/instrumentação
15.
Artigo em Inglês | MEDLINE | ID: mdl-24110405

RESUMO

Perimetry is essential for identifying visual field defects due to disorders of the eye and brain. However, young children are often unable to reliably perform the preferred method of visual field assessment known as automated static perimetry (ASP). This paper introduces a novel method of ASP specifically developed for children called Saccadic Vector Optokinetic Perimetry (SVOP). SVOP uses eye tracking to detect the natural saccadic eye response of gaze orientation towards visual field stimuli if they are seen. In this paper, the direction and magnitude of a sample of subject gaze responses to visual field stimuli is used to construct a software decision algorithm for use in SVOP. SVOP was clinically evaluated in a group of 24 subjects, comprising children and adults, with and without visual field defects, by comparison with an equivalent test on the Humphrey Field Analyser (HFA). SVOP provides promising visual field test results when compared with the reference HFA test, and has proven extremely useful in detecting visual field defects in children unable to perform traditional ASP.


Assuntos
Algoritmos , Automação , Movimentos Sacádicos/fisiologia , Testes de Campo Visual/métodos , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Fixação Ocular/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Campos Visuais/fisiologia , Adulto Jovem
16.
Doc Ophthalmol ; 126(2): 171-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23420465

RESUMO

BACKGROUND: The purpose of this paper is to report a case of idiopathic isolated fovea plana showing asymmetry in the multifocal electroretinogram (mfERG). METHODS: We carried out optical coherence tomography (OCT) imaging, macular pigment density measurement, genetic testing and electrophysiological testing with visual evoked potentials and mfERGs on a young, highly myopic female of Pakistani origin, who had good visual acuity and no nystagmus. RESULTS: OCT imaging revealed a complete absence of any foveal pit in either eye. Macular pigment density was normal and visual evoked potentials indicated normal chiasmal crossings, excluding albinism. Genetic testing revealed normal PAX6 coding data, excluding aniridia as a cause. mfERGs showed asymmetry consistent with off-centre fixation to the temporal side of the fovea in both eyes, but were otherwise normal. CONCLUSION: Lack of a foveal pit is a well-known finding in conditions such as oculocutaneous albinism and PAX6 gene-related aniridia. Isolated fovea plana is less common, and this case illustrates that the absence of a foveal pit does not necessarily result in a poor visual outcome. The finding of asymmetry in the mfERG in such a case is novel, and may indicate a functional adaptation to the structure of the fovea.


Assuntos
Albinismo Oculocutâneo/fisiopatologia , Eletrorretinografia/métodos , Potenciais Evocados Visuais/fisiologia , Fóvea Central/fisiopatologia , Quiasma Óptico/fisiopatologia , Albinismo Oculocutâneo/diagnóstico , Feminino , Fóvea Central/patologia , Humanos , Tomografia de Coerência Óptica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA